Short description:

IVY Aqua 02S is a water PH acidity level meter. This is a portable device that uses a battery (included). IVY Aqua 02S is a professional instrument for measuring PH level, salinity from 0.00 - 14 PH (calibrating powders included - in packets) It has high performance, pen-type design, fast numerical stability and accurate result.

Main Features:

  • 【Quick and Accurate】: Remove the protective cover, immerse the electrode of the pH tester in the solution, press the measurement button, and the reading can be obtained almost immediately. Built-in sensitive electrode sensor, accuracy: ±0.01pH, measuring range: 0-14pH, working temperature: 0 --60 , allowing you to quickly and accurately test your liquid.
  • 【Automatic Temperature Compensation】: The PH meter has a built-in (ATC) automatic temperature compensation function, which can accurately determine the pH value of the sample within the range of 0°C-60°C (32°F-140°F), so that the measurement data will not Affected by water temperature.
  • 【Automatic Calibration】: It needs to be recalibrated after a long period of inactivity or frequent use. The auto calibration function allows you to calibrate the PH test meter easily. Just use the buffer powder and press the "CAL" button to calibrate.
  • 【Wide Use】: The lightweight and portable size allows you to easily carry it with you, and measure it anytime, anywhere. It is suitable for testing the pH value of drinking water, liquid food, swimming pools, aquaculture, reverse osmosis systems, hot springs, hydroponics, etc. It is very suitable for scientific experiments in children's schools, testing different bottled water.

A device for determining the pH of water

  • • PH measurement: 0.0 - 14.0 pH
  • • Resolution: 0.01 pH
  • • Power supply: 2x 1.5V LR44 batteries (included)
  • • Accuracy: ± 0.1 pH (20 ° C) ± 0.2 pH
  • • Operating temperature: 0 - 60 ° C (32 - 140 ° F), ATC system!
  • • Calibration: factory, electronic, two-point / three-point
  • • Dimensions: 153 mm x 29 mm x 16 mm
  • • Weight: 51 years

Electronic pH meter

Automatic pH water level meter with a large, easy-to-read display. This allows for a quick estimate of the pH reagent level. The device is compact in size, so it is easy to use in various conditions. The measurement accuracy within 0.01 and the measurement time of about 1 second make the device easier to use.

The device can be used:

  • • Determination of pH of different liquids
  • • Aquaculture
  • • Gastronomy
  • • Agriculture
  • • Food industry
  • • Chemical industry
  • • To check the quality and suitability for use of glycol solar fluid
  • The ATC function allows you to accurately determine the pH value regardless of the temperature of the liquid.

Measurement method

Remove the cover of the device. Crystals appearing on the surface of the electrode are a natural phenomenon and must be removed before measurement.
Immerse the device in water to the level indicated on the body. Mix gently, wait about 30 seconds and the display will stabilize.
When you're done, read the measurement. Do not forget to dry the device after each measurement. You can protect the electrodes with a special electrode storage fluid.
ATTENTION! If readings differ for the same fluid, calibrate the meter using the solutions provided and the calibration button on the body. A description of the calibration can be found in the user manual of the device.

pH meter calibration

  • 1. To open the calibration powder, add 250ml distilled or pure water (do not use tap water or mineral water). Dip the pH electrode into standard mixed phosphate buffer pH 6.86 and shake gently.
  • 2. Press the CAL button, automatic calibration will occur until the displayed value and the standard pH 6.9 buffer solution match the ambient temperature.
  • 3. As above, the electrode was placed in a standard potassium bicarbonate phosphorous acid buffer solution pH 4.01.
  • 4. About two minutes or so. The displayed value must be within the error tolerance compared to the pH value of the buffer solution.

Device description

  • LCD display
  • Power button
  • Automatic calibration button
  • Plastic Protective Cover

The set contains

  • • PH meter + batteries
  • • 2 250 ml reagent set for calibration (ph 4.01, ph 6.86, ph 9.18)
Specification
Similar items
IVY Aqua A1 3in1 Water Quality & Hardness meter pen measures TDS EC Temperature + Pouch White (TDS-A1)
17.32 EUR
Buy
IVY Aqua ST-02 4in1 Garden Soil Testing device measure Sunlight Moisture Temperature PH Black (ST-02)
18.84 EUR
Buy
IVY Aqua 009A Water PH measure pen with ATC & LCD for Aqualrium Pool Food Garden Wine Yellow (PH-009A)
16.42 EUR
Buy